一、電機的特性試驗和技術規范的再修訂
當(dang)一臺(tai)普(pu)通(tong)電(dian)(dian)(dian)動(dong)機(ji)(ji)由(you)變頻提供電(dian)(dian)(dian)源(yuan)時(shi),其變頻器輸(shu)(shu)出端的(de)(de)(de)(de)電(dian)(dian)(dian)壓和(he)電(dian)(dian)(dian)流(liu)諧(xie)波分(fen)(fen)量會使電(dian)(dian)(dian)機(ji)(ji)的(de)(de)(de)(de)損(sun)耗(hao)(hao)(hao)增(zeng)(zeng)(zeng)加、效率(lv)降低(di)、溫度升高。高次(ci)諧(xie)波引起(qi)損(sun)耗(hao)(hao)(hao)的(de)(de)(de)(de)增(zeng)(zeng)(zeng)加主要表現在(zai)定子(zi)和(he)轉子(zi)的(de)(de)(de)(de)銅(tong)耗(hao)(hao)(hao)、鐵損(sun)及附加損(sun)耗(hao)(hao)(hao)的(de)(de)(de)(de)增(zeng)(zeng)(zeng)加。其中,轉子(zi)銅(tong)耗(hao)(hao)(hao)最為(wei)(wei)顯著,因為(wei)(wei)異(yi)步(bu)電(dian)(dian)(dian)機(ji)(ji)總是(shi)(shi)在(zai)轉差接(jie)近1的(de)(de)(de)(de)狀態下(xia)旋轉,所以(yi)(yi)轉子(zi)銅(tong)耗(hao)(hao)(hao)非常大。在(zai)普(pu)通(tong)異(yi)步(bu)電(dian)(dian)(dian)機(ji)(ji)中,為(wei)(wei)改善電(dian)(dian)(dian)機(ji)(ji)啟動(dong)性能,轉子(zi)的(de)(de)(de)(de)集膚效應使實際阻(zu)抗增(zeng)(zeng)(zeng)加,從而使銅(tong)耗(hao)(hao)(hao)增(zeng)(zeng)(zeng)大。另一方面,由(you)于電(dian)(dian)(dian)機(ji)(ji)線(xian)圈(quan)(quan)之間存在(zai)分(fen)(fen)布電(dian)(dian)(dian)容,當(dang)高次(ci)諧(xie)波電(dian)(dian)(dian)壓輸(shu)(shu)入時(shi),各線(xian)圈(quan)(quan)之間的(de)(de)(de)(de)電(dian)(dian)(dian)壓是(shi)(shi)不均勻(yun)的(de)(de)(de)(de),這種長期反復作用使定子(zi)線(xian)圈(quan)(quan)某一部分(fen)(fen)的(de)(de)(de)(de)絕緣造成損(sun)傷,從而產(chan)生線(xian)圈(quan)(quan)老化,這在(zai)普(pu)通(tong)異(yi)步(bu)電(dian)(dian)(dian)動(dong)機(ji)(ji)的(de)(de)(de)(de)絕緣結構方面是(shi)(shi)難以(yi)(yi)接(jie)受的(de)(de)(de)(de)。
另外,電機的電磁回路不可能做到對稱,所以變頻器輸出電源中所含有的各次諧波分量將與電磁回路中固有的空間諧波分量相互作用形成各種電磁脈動。同時,電機因處在頻率不斷調節的工作狀態下,很容易與電機機械部分產生機械共振,造成電機機械部位的損壞。
,在變頻調速改造工程中,為了避免變頻調速系統在運行時出現上述問題,技術設計時必須考慮和電動機制造廠家進行技術合作,對電動機的相關特性進行調速實驗,重新修訂原電動機的技術規范。
二、電力電纜選型要點和敷設要求
由于變頻器輸出端與電機之間的聯系采用電纜附設方式,且線路各相均存在對地電容,所以運行時線路上的電容電流是不相等的。如果電纜附設距離較長,且線路中又存在高次諧波電流,那么一旦發生單相接地時,故障電容電流所點燃的電弧熄滅時間過長,會使這端電纜發熱,造成非故障絕緣。
所以,在變頻調速改造工程中,針對輸出電源電纜,考慮電纜結構上的三相對稱和屏蔽,將電纜截面適當增加,敷設長度不超過限定值(100m),如果原輸出電源電纜為非屏蔽或截面的栽流量裕度小于2,應更換符合要求的電力電纜。
現場敷設施工時要將電源電纜與控制電纜和信號電纜分開敷設,避免由電源電纜中高次諧波產生的磁場干擾其他信號。